VG Internal Gear Pump - High Pressure Single Pump Supplier & Factory in China for Reliable Hydraulic Systems
Model Representation
| VG1 | -63 | R | E | W | -A1 |
| Series | ml/r Displacement | Rotation | Shaft type | Sealing material | Design number |
| VGH0 | 003, 004, 005 |
Viewed from shaft end of pump R = Right hand for clockwise L = Left hand for counter-clockwise |
K = Straight key shaft |
W = (Buna) NBR V = (Viton) FKM |
1K |
| VG0 | 8, 10, 13, 16, 20, 25, 28 |
E = Straight key shaft R = SAE Spline shaft |
A1 | ||
| VG1 | 25, 32, 40, 50, 63 50H, 63H |
||||
| VG2 | 80, 100, 125, 145, 160 |
Technical Data
| Series | ml/r | ml/r | Mpa | Mpa | r/min | kg |
|---|---|---|---|---|---|---|
| Displacement | Theory Displacement | Rated Pressure | Max. pressure | Max. speed | Weight | |
| VGH0 | 3 | 3 | 33 | 40 | 4200 | 4.6 |
| 4 | 4 | 4.8 | ||||
| 5 | 5 | 4.8 | ||||
| VG0 | 8 | 8.2 | 31.5 | 35 | 3000 | 4.6 |
| 10 | 10.2 | 4.8 | ||||
| 13 | 13.3 | 4.9 | ||||
| 16 | 16 | 5.2 | ||||
| 20 | 20 | 25 | 30 | 5.6 | ||
| 25 | 24 | 6 | ||||
| 28 | 27 | 6.4 | ||||
| VG1 | 25 | 25.3 | 31.5 | 35 | 14.5 | |
| 32 | 32.7 | 15 | ||||
| 40 | 40.1 | 16 | ||||
| 50 | 50.7 | 17 | ||||
| 63 | 63.7 | 25 | 30 | 18.5 | ||
| VG2 | 80 | 81.4 | 31.5 | 35 | 43.5 | |
| 100 | 100.2 | 45.5 | ||||
| 125 | 125.3 | 48 | ||||
| 145 | 145.2 | 25 | 28 | 50 | ||
| 160 | 162.8 | 21 | 26 | 52 |
1500r/min Characteristic curve
2000r/min Characteristic curve
1500r/min Noise curve
2000r/min Characteristic curve
VGH0 Installation Dimensions
VG0 Installation Dimensions
| Model | L1 | L2 | A | B | C | D | E | F | G |
|---|---|---|---|---|---|---|---|---|---|
| VG0-08 | 107 | 54 | 38.1 | 17.5 | Φ13 | M8 Depth 13 | 47.6 | 22.2 | Φ19 |
| VG0-10 | 111 | 56 | 52.4 | 26.2 | |||||
| VG0-13 | 117.5 | 59.25 | |||||||
| VG0-16 | 123 | 62 | |||||||
| VG0-20 | 131 | 66 | 47.6 | 22.2 | Φ18 | M10 Depth 15 | 58.7 | 30.2 | Φ26 |
| VG0-25 | 139 | 70 | Φ19 | Φ28 | |||||
| VG0-28 | 145 | 73 |
VG1 Installation Dimensions
| Model | L1 | L2 | A | B | C |
|---|---|---|---|---|---|
| VG1-25 | 139 | 73 | 47.6 | 22.2 | Φ18 |
| VG1-32 | 146 | 76.5 | |||
| VG1-40 | 153 | 80 | 52.4 | 26.2 | Φ20 |
| VG1-50 | 163 | 85 | |||
| VG1-63 | 177 | 92 | |||
| VG1-50H | 163 | 85 | see page 11 oil port size | ||
| VG1-63H | 177 | 92 | |||
VG2 Installation Dimensions
| Model | L1 | L2 | A | B | C | D | E | F | G | H |
|---|---|---|---|---|---|---|---|---|---|---|
| VG2-80 | 204 | 109.5 | 69.9 | 35.7 | Φ32 | M12 Depth 20 | 77.8 | 42.9 | Φ51 | M12 Depth 20 |
| VG2-100 | 213 | 114 | ||||||||
| VG2-125 | 225 | 120 | 79.4 | 36.5 | Φ38 | M16 Depth 25 | 88.9 | 50.8 | Φ63.5 | |
| VG2-145 | 235.5 | 124.75 | ||||||||
| VG2-160 | 243 | 129 | 106.4 | 61.9 | Φ76 | M16 Depth 25 |
VG series single pump inlet and outlet oil port connection size
| Model | Specifications | S | A1 | B1 | C1 | Corresponding flange | P | A2 | B2 | C2 | Corresponding flange |
|---|---|---|---|---|---|---|---|---|---|---|---|
| VG0 | 8 | 19 | 47.6 | 22.2 | M10 Depth 15 | F06 | 13 | 38.1 | 17.5 | M8 Depth 13 | F04 |
| 10 | 52.4 | 26.2 | F08 | ||||||||
| 13 | |||||||||||
| 16 | |||||||||||
| 20 | 26 | 58.7 | 30.2 | F10 | 18 | 47.6 | 22.2 | M10 Depth 15 | F06 | ||
| 25 | 28 | 19 | |||||||||
| 28 | |||||||||||
| VG1 | 25 | 32 | 58.7 | 30.2 | M10 Depth 17 | F10 | 18 | 47.6 | 22.2 | M10 Depth 17 | F06 |
| 32 | |||||||||||
| 40 | 20 | 52.4 | 26.2 | F08 | |||||||
| 50 | |||||||||||
| 63 | |||||||||||
| 50(H) | 38 | 69.9 | 35.7 | M12 Depth 20 | F12 | ||||||
| 63(H) | 51 | 77.8 | 42.9 | F16 | |||||||
| VG2 | 80 | 51 | 77.8 | 42.9 | M12 Depth 20 | F16 | 32 | 69.9 | 35.7 | M12 Depth 20 | F12 |
| 100 | |||||||||||
| 125 | 63.5 | 88.9 | 50.8 | F20 | 38 | 79.4 | 36.5 | M16 Depth 25 | F14 | ||
| 145 | |||||||||||
| 160 | 76 | 106.4 | 61.9 | M16 Depth 25 | F24 |
Product Display
Frequently Asked Questions
What does the model code "VG1-63REW-A1" stand for?
According to the model representation, "VG1-63REW-A1" stands for the VG1 Series pump with a displacement of 63 ml/r, right-hand rotation (clockwise, viewed from the shaft end), a straight key shaft (E), NBR sealing material (W), and design number A1.
What sealing material options are available for the VG series pump?
The VG series single pumps support two sealing materials: W (Buna NBR) and V (Viton FKM), allowing compatibility with different operating temperatures and hydraulic fluids.
What is the maximum speed limit for the VGH0, VG0, VG1, and VG2 pumps?
The VGH0 series pump has a maximum speed of 4200 r/min. The VG0, VG1, and VG2 series pumps have a maximum speed limit of 3000 r/min.
How is the rotation direction of the pump determined?
The rotation direction is viewed from the shaft end of the pump. "R" designates right-hand (clockwise) rotation, while "L" designates left-hand (counter-clockwise) rotation.
What are the rated and maximum pressure specifications for the VG series?
The rated pressure for VGH0 is 33 MPa (max pressure 40 MPa). For the VG0, VG1, and VG2 series, the rated pressure is generally 31.5 MPa (max pressure 35 MPa), except for specific displacement models like VG0-20/25/28, VG1-63, and VG2-145/160, which operate at lower pressure ranges.

Industrial Automation