China Ultract Series Physis Servo Motor Surface Mount – Reliable Suppliers and Factory Solutions
Surface Mount Model Description
Motor type U31007F30(70Nm,3000rpm), 380Vac, servo fan cooling, resolver TS2640N321E64, safety brake, signal circular connector only, with Key on shaft, standard feet.
PHYSIS surface mount(air cooling) ULTRACT Series
Parameters
| Motor Model | Rated speed | Rated torque | Rated Power | Rated Current | Rated Voltage | Peak Torque | Torque constant | Moment of Inertia | Rated Frequncy |
| Unit | rpm | Nm | kW | A | V | Nm | Nm/A | Kg*cm2 | Hz |
| U1004F15.3 | 1500 | 38 | 6.0 | 11.6 | 380 | 105 | 3.32 | 50 | 100 |
| U1004F17.3 | 1700 | 38.9 | 7 | 15.2 | 380 | 105 | 2.81 | 50 | 113 |
| U1004F20.3 | 2000 | 42 | 8.8 | 18.8 | 380 | 105 | 2.37 | 50 | 133 |
| U1005F15.3 | 1500 | 55 | 8.6 | 16.6 | 380 | 157 | 3.31 | 70 | 100 |
| U1005F17.3 | 1700 | 57 | 10 | 20.4 | 380 | 157 | 2.81 | 70 | 113 |
| U1005F20.3 | 2000 | 58 | 12 | 24.3 | 380 | 157 | 2.6 | 70 | 133 |
| U1007F15.3 | 1500 | 74 | 11.6 | 23.9 | 380 | 210 | 3.37 | 90 | 100 |
| U1007F17.3 | 1700 | 80 | 14 | 28.2 | 380 | 210 | 2.85 | 90 | 113 |
| U1007F20.3 | 2000 | 87 | 18.2 | 36.7 | 380 | 210 | 2.53 | 90 | 133 |
| U1008F15.3 | 1500 | 103 | 16.4 | 33.2 | 380 | 260 | 3.38 | 110 | 100 |
| U1008F17.3 | 1700 | 96.2 | 17.6 | 35.1 | 380 | 260 | 2.98 | 110 | 113 |
| U1008F20.3 | 2000 | 95.6 | 20.4 | 40.1 | 380 | 260 | 2.58 | 110 | 133 |
| U1010F15.3 | 1500 | 128 | 22 | 41 | 380 | 310 | 3.3 | 130 | 100 |
| U1010F18.3 | 1800 | 122 | 23 | 44 | 380 | 310 | 2.87 | 130 | 113 |
| U1010F20.3 | 2000 | 135 | 28.3 | 60.5 | 380 | 310 | 2.37 | 130 | 133 |
| U1013F15.3 | 1500 | 186 | 29 | 61 | 380 | 410 | 3.26 | 170 | 100 |
| U1013F17.3 | 1700 | 164.2 | 28.7 | 55.39 | 380 | 410 | 3.19 | 170 | 113 |
| U1013F20.3 | 2000 | 175 | 36.7 | 73.7 | 380 | 410 | 2.53 | 170 | 133 |
| U1315F15.3 | 1500 | 195.6 | 30.5 | 71.5 | 380 | 450 | 3.02 | 317 | 100 |
| U1315F17.3 | 1700 | 195.29 | 35.9 | 72.9 | 380 | 450 | 2.98 | 317 | 113 |
| U1315F20.3 | 2000 | 191 | 40 | 97.8 | 380 | 450 | 2.15 | 317 | 133 |
| U1320F15.3 | 1500 | 210 | 33 | 62 | 380 | 550 | 3.43 | 410 | 100 |
| U1320F17.3 | 1700 | 229 | 39.4 | 92.6 | 380 | 550 | 2.94 | 410 | 113 |
| U1320F18.3 | 1800 | 232 | 44 | 96.46 | 380 | 550 | 2.64 | 410 | 120 |
| U1320F20.3 | 2000 | 269 | 56.3 | 120.7 | 380 | 550 | 2.37 | 410 | 133 |
| U1325F15.3 | 1500 | 308 | 49.6 | 99.9 | 380 | 690 | 3.43 | 500 | 100 |
| U1325F17.3 | 1700 | 304.5 | 55.4 | 111 | 380 | 690 | 3.05 | 500 | 113 |
| U1325F20.3 | 2000 | 291.2 | 71.9 | 141.5 | 380 | 690 | 2.29 | 500 | 133 |
| U1330F15.3 | 1500 | 380 | 60 | 106 | 380 | 830 | 3.56 | 593 | 100 |
| U1330F17.3 | 1700 | 399 | 71 | 155.5 | 380 | 830 | 2.84 | 593 | 113 |
| U1330F20.3 | 2000 | 389 | 81.4 | 155.3 | 380 | 830 | 2.67 | 593 | 133 |
| U1340F15.3 | 1500 | 450 | 70 | 130 | 380 | 1100 | 3.56 | 777 | 100 |
| U1340F20.3 | 2000 | 511 | 107 | 229.7 | 380 | 1100 | 2.37 | 777 | 133 |
1. Max speed: If you don't use the flux-weakening control function, the max rotational speed will be higher 500rpm than rated speed. If you use the flux-weakening control function, the max rotational speed is decided by the drive.
2. Pole Number: The pole number of the above motor is 8 poles, which is 4 pairs of poles.
PHYSIS surface mount(Oil Cooling) Parameters
| Motor model | Rated Speed | Rated Torque | Rated Power | Rated Current | Rated Voltage | Peak Torque | Torque Constant |
| Unit | rpm | Nm | Kw | A | V | Nm | Nm/A |
| U1008Y203 | 2000 | 114 | 24 | 47.3 | 366 | 255 | 2.71 |
| U1010Y173 | 1700 | 135 | 24 | 48 | 360 | 310 | 3.22 |
| U1010Y203 | 2000 | 138 | 28.8 | 56.2 | 350 | 310 | 2.74 |
| U1013Y203 | 2000 | 186 | 38.9 | 74.7 | 377 | 410 | 2.78 |
| U1315Y203 | 2000 | 221 | 46.2 | 115.4 | 363 | 363 | 2.31 |
| U1320Y173 | 1700 | 262 | 46.6 | 102 | 390 | 550 | 3.08 |
| U1320Y203 | 2000 | 301 | 63 | 147.9 | 391 | 550 | 2.46 |
| U1325Y173 | 1700 | 369 | 65.7 | 145.1 | 408 | 675 | 3.08 |
| U1330Y153 | 1500 | 425 | 66.8 | 173.1 | 320 | 830 | 2.89 |
| U1340Y153 | 1500 | 567 | 89.1 | 208 | 355 | 1100 | 3.21 |
| U18050Y153 | 1500 | 662 | 104 | 175 | 380 | 1795 | 4.3 |
| U18070Y153 | 1500 | 1025 | 161 | 344 | 380 | 3482 | 3.36 |
| U18100Y153 | 1500 | 1337 | 210 | 382 | 380 | 4643 | 4.03 |
Surface Mount series Installation dimensions
10F Series standard shaft motor
| Type | U1004F | U1005F | U1007F | U1008F | U1010F | U1013F |
| M | 267 | 285 | 312 | 354 | 396 | 471 |
| L(Resolver R3,R4,etc) | 338.5 | 377.5 | 413.5 | 446.5 | 487.5 | 554.5 |
13F Series standard shaft motor
| Motor Model | A1 | A2 | ΦD1 | B1 | H1 | KEY | |
| In ≤ 150A | In>150A | ||||||
| U1315F | 513.5 | 553.5 | 360 | 48j8 | 14 | 51.5 | 14x9x90 |
| U1320F | 566.5 | 606.5 | 370 | 48j7 | 14 | 51.5 | 14x9x91 |
| U1325F | 620 | 660 | 476 | 48j8 | 14 | 51.5 | 14x9x92 |
| U1330F | 673.5 | 713.5 | 476 | 48j9(60m6) | 14(18) | 51.5(64) | 14x9x93(18x11x90) |
| U1340F | 780.5 | 820.5 | 583 | 60m6 | 18 | 64 | 18x11x90 |
Features & Benefits
High grade rare earth permanent magnets, mature electromagnetic and cooling solutions, provide GB30549, the highest level and IEC60034 energy efficiency, the highest IE5 solutions.
High strength alloy material and polymer material, high torque/volume ratio and power/volume ratio, is 2-3 times of the ordinary motor.
Precision automatic manufacturing process, high precision core parts, mature electromagnetic scheme, motor running more smooth and stable, lower noise.
The seven sizes are stable for multiple application scenarios and can also provide a full range of platform-based non-standard customization solutions.
Applications
Product Display
Frequently Asked Questions (FAQ)
1. What cooling options are available for the PHYSIS surface mount motors?
The PHYSIS Surface Mount ULTRACT Series features both Air Cooling (F Series) and Oil Cooling (Y Series) models to accommodate different operating environments and thermal management requirements.
2. How do I decode the ordering code for these motors?
The order code specifies motor parameters such as type, rated torque, rated speed, voltage, cooling type, feedback sensor (e.g., resolver), safety brake, shaft configuration, and mounting feet. For example, code U3 10 07 F 30 3 R4 B YO K b1 indicates a 70Nm, 3000rpm air-cooled motor with safety brake and key on shaft.
3. What is the maximum speed capacity of the Air Cooling (F Series) motors?
Without flux-weakening control, the maximum rotational speed is 500 rpm higher than the rated speed. With flux-weakening control, the maximum rotational speed is determined by the drive system.
4. How many poles do these permanent magnet motors have?
The standard PHYSIS Surface Mount motors featured in the parameters have a pole number of 8 poles, which corresponds to 4 pairs of poles.
5. In what typical machinery are these motors applied?
These motors are widely used in heavy industrial applications such as Injection Molding Machines, Plastic Extruders, Blow Molding Machines, Shoe Making Machinery, Die Casting Machines, Hydraulic Presses, Brick Making Machines, Baling Presses, Aluminum Extrusion Presses, and Powder Metallurgy Equipment.
6. What efficiency standard do the PHYSIS ULTRACT Series motors achieve?
Thanks to high-grade rare earth permanent magnets and optimized electromagnetic designs, they comply with the GB30549 standard and meet the highest IE5 energy efficiency requirements under IEC60034.

Industrial Automation