| Motor Model | Rated Speed (rpm) | Rated Torque (Nm) | Rated Power (kW) | Rated Current (A) | Rated Voltage (V) | Peak Torque (Nm) | Torque Constant (Nm/A) | Moment of Inertia (Kg*cm²) | Rated Frequency (Hz) |
|---|---|---|---|---|---|---|---|---|---|
| U1004F15.3 | 1500 | 38 | 6.0 | 11.6 | 380 | 105 | 3.32 | 50 | 100 |
| U1004F17.3 | 1700 | 38.9 | 7 | 15.2 | 380 | 105 | 2.81 | 50 | 113 |
| U1004F20.3 | 2000 | 42 | 8.8 | 18.8 | 380 | 105 | 2.37 | 50 | 133 |
| U1005F15.3 | 1500 | 55 | 8.6 | 16.6 | 380 | 157 | 3.31 | 70 | 100 |
| U1005F17.3 | 1700 | 57 | 10 | 20.4 | 380 | 157 | 2.81 | 70 | 113 |
| U1005F20.3 | 2000 | 58 | 12 | 24.3 | 380 | 157 | 2.6 | 70 | 133 |
| U1007F15.3 | 1500 | 74 | 11.6 | 23.9 | 380 | 210 | 3.37 | 90 | 100 |
| U1007F17.3 | 1700 | 80 | 14 | 28.2 | 380 | 210 | 2.85 | 90 | 113 |
| U1007F20.3 | 2000 | 87 | 18.2 | 36.7 | 380 | 210 | 2.53 | 90 | 133 |
| U1008F15.3 | 1500 | 103 | 16.4 | 33.2 | 380 | 260 | 3.38 | 110 | 100 |
| U1008F17.3 | 1700 | 96.2 | 17.6 | 35.1 | 380 | 260 | 2.98 | 110 | 113 |
| U1008F20.3 | 2000 | 95.6 | 20.4 | 40.1 | 380 | 260 | 2.58 | 110 | 133 |
| U1010F15.3 | 1500 | 128 | 22 | 41 | 380 | 310 | 3.3 | 130 | 100 |
| U1010F18.3 | 1800 | 122 | 23 | 44 | 380 | 310 | 2.87 | 130 | 113 |
| U1010F20.3 | 2000 | 135 | 28.3 | 60.5 | 380 | 310 | 2.37 | 130 | 133 |
| U1013F15.3 | 1500 | 186 | 29 | 61 | 380 | 410 | 3.26 | 170 | 100 |
| U1013F17.3 | 1700 | 164.2 | 28.7 | 55.39 | 380 | 410 | 3.19 | 170 | 113 |
| U1013F20.3 | 2000 | 175 | 36.7 | 73.7 | 380 | 410 | 2.53 | 170 | 133 |
| U1315F15.3 | 1500 | 195.6 | 30.5 | 71.5 | 380 | 450 | 3.02 | 317 | 100 |
| U1315F17.3 | 1700 | 195.29 | 35.9 | 72.9 | 380 | 450 | 2.98 | 317 | 113 |
| U1315F20.3 | 2000 | 191 | 40 | 97.8 | 380 | 450 | 2.15 | 317 | 133 |
| U1320F15.3 | 1500 | 210 | 33 | 62 | 380 | 550 | 3.43 | 410 | 100 |
| U1320F17.3 | 1700 | 229 | 39.4 | 92.6 | 380 | 550 | 2.94 | 410 | 113 |
| U1320F18.3 | 1800 | 232 | 44 | 96.46 | 380 | 550 | 2.64 | 410 | 120 |
| U1320F20.3 | 2000 | 269 | 56.3 | 120.7 | 380 | 550 | 2.37 | 410 | 133 |
| U1325F15.3 | 1500 | 308 | 49.6 | 99.9 | 380 | 690 | 3.43 | 500 | 100 |
| U1325F17.3 | 1700 | 304.5 | 55.4 | 111 | 380 | 690 | 3.05 | 500 | 113 |
| U1325F20.3 | 2000 | 291.2 | 71.9 | 141.5 | 380 | 690 | 2.29 | 500 | 133 |
| U1330F15.3 | 1500 | 380 | 60 | 106 | 380 | 830 | 3.56 | 593 | 100 |
| U1330F17.3 | 1700 | 399 | 71 | 155.5 | 380 | 830 | 2.84 | 593 | 113 |
| U1330F20.3 | 2000 | 389 | 81.4 | 155.3 | 380 | 830 | 2.67 | 593 | 133 |
| U1340F15.3 | 1500 | 450 | 70 | 130 | 380 | 1100 | 3.56 | 777 | 100 |
| U1340F20.3 | 2000 | 511 | 107 | 229.7 | 380 | 1100 | 2.37 | 777 | 133 |
Note:
1. Max speed: If you don't use the flux-weakening control function, the max rotational speed will be 500rpm higher than the rated speed. If you use the flux-weakening control function, the max rotational speed is decided by the drive.
2. Pole Number: The pole number of the above motor models is 8 poles (4 pairs of poles).
1. Max speed: If you don't use the flux-weakening control function, the max rotational speed will be 500rpm higher than the rated speed. If you use the flux-weakening control function, the max rotational speed is decided by the drive.
2. Pole Number: The pole number of the above motor models is 8 poles (4 pairs of poles).
PHYSIS Surface Mount (Oil Cooling) Parameters
| Motor Model | Rated Speed (rpm) | Rated Torque (Nm) | Rated Power (kW) | Rated Current (A) | Rated Voltage (V) | Peak Torque (Nm) | Torque Constant (Nm/A) |
|---|---|---|---|---|---|---|---|
| U1008Y203 | 2000 | 114 | 24 | 47.3 | 366 | 255 | 2.71 |
| U1010Y173 | 1700 | 135 | 24 | 48 | 360 | 310 | 3.22 |
| U1010Y203 | 2000 | 138 | 28.8 | 56.2 | 350 | 310 | 2.74 |
| U1013Y203 | 2000 | 186 | 38.9 | 74.7 | 377 | 410 | 2.78 |
| U1315Y203 | 2000 | 221 | 46.2 | 115.4 | 363 | 363 | 2.31 |
| U1320Y173 | 1700 | 262 | 46.6 | 102 | 390 | 550 | 3.08 |
| U1320Y203 | 2000 | 301 | 63 | 147.9 | 391 | 550 | 2.46 |
| U1325Y173 | 1700 | 369 | 65.7 | 145.1 | 408 | 675 | 3.08 |
| U1330Y153 | 1500 | 425 | 66.8 | 173.1 | 320 | 830 | 2.89 |
| U1340Y153 | 1500 | 567 | 89.1 | 208 | 355 | 1100 | 3.21 |
| U18050Y153 | 1500 | 662 | 104 | 175 | 380 | 1795 | 4.3 |
| U18070Y153 | 1500 | 1025 | 161 | 344 | 380 | 3482 | 3.36 |
| U18100Y153 | 1500 | 1337 | 210 | 382 | 380 | 4643 | 4.03 |
Surface Mount Series Installation Dimensions
10F Series Standard Shaft Motor
| Type | U1004F | U1005F | U1007F | U1008F | U1010F | U1013F |
|---|---|---|---|---|---|---|
| M | 267 | 285 | 312 | 354 | 396 | 471 |
| L (Resolver R3, R4, etc) | 338.5 | 377.5 | 413.5 | 446.5 | 487.5 | 554.5 |
13F Series Standard Shaft Motor
| Motor Model | A1 | A2 | ΦD1 | B1 | H1 | KEY | |
|---|---|---|---|---|---|---|---|
| In ≤ 150A | In > 150A | ||||||
| U1315F | 513.5 | 553.5 | 360 | 48j8 | 14 | 51.5 | 14x9x90 |
| U1320F | 566.5 | 606.5 | 370 | 48j7 | 14 | 51.5 | 14x9x91 |
| U1325F | 620 | 660 | 476 | 48j8 | 14 | 51.5 | 14x9x92 |
| U1330F | 673.5 | 713.5 | 476 | 48j9 (60m6) | 14 (18) | 51.5 (64) | 14x9x93 (18x11x90) |
| U1340F | 780.5 | 820.5 | 583 | 60m6 | 18 | 64 | 18x11x90 |
Features & Benefits
High efficiency
High grade rare earth permanent magnets, mature electromagnetic and cooling solutions, provide GB30549 (the highest level) and IEC60034 energy efficiency (the highest IE5 solutions).
Lightweight
High strength alloy material and polymer material, high torque/volume ratio and power/volume ratio, is 2-3 times of the ordinary motor.
Low noise
Precision automatic manufacturing process, high precision core parts, mature electromagnetic scheme, motor running more smooth and stable, lower noise.
Flexible
The seven sizes are stable for multiple application scenarios and can also provide a full range of platform-based non-standard customization solutions.
Applications
Injection Molding Machine
Plastic Extruder
Blow Molding Machine
Shoe Making Machinery
Die Casting Machine
Hydraulic Press
Brick Making Machine
Baling Press
Aluminum Extrusion Press
Powder Metallurgy Equipment
Product Display
Frequently Asked Questions (FAQ)
What does the order code U3 10 07 F 30 3 R4 B YO K b1 represent?
This order code represents motor model type U31007F30 (featuring a 70Nm rated torque and 3000rpm rated speed), configured for a 380Vac power supply, equipped with servo fan cooling, a resolver TS2640N321E64, a safety brake, a signal circular connector only, a keyed shaft, and standard mounting feet.
What cooling methods are available for the PHYSIS ULTRACT series?
The PHYSIS ULTRACT series provides two main cooling configurations: Air Cooling (F Series) and Oil Cooling (Y Series) to ensure optimal heat dissipation based on the application environment.
How does the flux-weakening function affect the maximum rotational speed?
Without the flux-weakening control function, the maximum speed will run 500rpm higher than the rated speed. If the flux-weakening control function is used, the maximum rotational speed is determined by the configuration of the drive system.
What is the pole configuration of the air-cooled motors?
The ULTRACT air-cooled motors listed feature an 8-pole configuration, which constitutes 4 pairs of poles.
What energy efficiency standards do PHYSIS motors meet?
PHYSIS motors utilize high-grade rare earth permanent magnets to achieve the highest level of GB30549 energy efficiency and IEC60034 IE5 efficiency standards.